Cross ventilation

Last updated
Cross-breezes work when two windows are opposite of each other. Window through a window in Roe gard cafe 1.jpg
Cross-breezes work when two windows are opposite of each other.

Cross ventilation is a natural phenomenon where wind, fresh air or a breeze enters upon an opening, such as a window, and flows directly through the space and exits through an opening on the opposite side of the building (where the air pressure is lower). This produces a cool stream of air and as well as a current across the room from the exposed area to the sheltered area. Other terms used for the effect include, cross-breeze, cross-draft, wind effect ventilation and cross-flow ventilation. [1]

Contents

Windows or vents positioned on opposite sides of the room allow passive breezes a pathway through the structure, which circulate the air and provide passive cooling. [1] Cross ventilation is a wind-driven effect and requires no energy, in addition to being the most effective method of wind ventilation. A commonly used technique to remove pollutants and heat in an indoor environment, cross ventilation can also decrease or even obviate the need for an air-conditioner and can improve indoor air quality. [2]

Process

The phenomenon occurs when openings in an environment (including vehicles) or building (houses, factories, sheds, etc) are set on opposite or adjoining walls, which allow air to enter and exit, thus creating a current of air across the interior environment. [3]

There is also a pressure difference between the opposite sides of the establishment. The effect is mostly driven by the wind, whereby the air is pulled into the building on the high pressure windward part and is pushed out on the low pressure downwind side of the establishment (because of the pressure difference between the openings). A wind's effect on a structure creates regions that have positive pressure on the building's upwind area and a negative pressure on the downwind side. Thus, the building shape and local wind patterns are critical in making wind pressures that force airflow through its openings. [4]

If the windows on both sides of the buildings are opened, the overpressure on the side facing the wind, and/or low pressure on the adjacent protected side, will make a current of air through the room from the uncovered side towards the sheltered side. If there are windows on both sides in a building, cross ventilation is appropriate where the width of the room is up to five times the floor-to-ceiling height. If openings are only one side then wind-driven ventilation is more suited for structures where the width is around 2.5 times the floor to ceiling height. [5]

Factors

Window size is important for cross ventilation Covid aha ventilation 3.svg
Window size is important for cross ventilation

Cross ventilation relies on many factors, such as the tightness of the establishment, wind direction and how much wind is available, its potential travel through chimneys, vents and other openings in the home. Casement windows can be installed to improve cross-breezes. Air quality may also affect cross ventilation.

Although cross ventilation is generally more direct at its job than stack ventilation, its cons include its effects being unproductive on hot, still days, when it is most necessary. Moreover, cross ventilation is generally only suitable for narrow buildings. The contrasting height of the openings (walls, sill, panels or furniture) ordered by the space also immediately influence the level and velocity of ventilation. [1]

Effectiveness

Cross ventilation works well in climates with hotter temperatures, where the system allows continual changes of the air within the building, refreshing it and reducing the temperature inside the structure and also when the window on the windward side of the building is not opened as much as the one on the leeward side. Cross ventilation will not be efficacious if the windows are more than 12m apart and if a window is behind a door that is regularly shut. [6]

An opened window that faces a prevailing wind and is conjugated with another window on the opposite side of a building will supply natural ventilation for fresh air. A decent and effective cross ventilation will remove heat from the interior and keep indoor air temperatures approximately 1.5 °C (2.7°F) below the outdoor air temperatures, ensuring that there is a steady inflow and outflow of fresh air inside the building. [7]

Besides windows, other openings like brise soleils, doors, louvers or ventilation grills and ducts can also work as effective ventilation openings, though an awning window provides the least effectivity. The wind surrounding building structures is important when it comes to assessing the air quality and thermal comfort indoors since both air and heat exchange rely heavily on the wind pressure on the exterior of the building. For the best airflow, the windward windows of the occupied space should not be opened as much as those on the leeward side. [8] Disadvantages of wind-driven ventilation include capricious wind speeds and directions (which may create a strong unpleasant draft), and the polluted air from the outside that may tarnish the indoor air quality. [9]

Cross ventilation is not recommended for use in disease prevention when air is being moved by the cross ventilation from an unclean area into a clean area. [10]

Types

In a windcatcher, wind is forced down on the windward side and exits on the leeward side, using the stack effect. Malqaf.svg
In a windcatcher, wind is forced down on the windward side and exits on the leeward side, using the stack effect.

There are four different types of cross ventilation: [11]

Equation

For a simple volume with two openings, the cross wind flow rate can be calculated using the following equation: [12]

where is the far-field wind speed; is a local pressure drag coefficient for the building, defined at the location of the upstream opening; is a local pressure drag coefficient for the building, defined at the location of the downstream opening; is the cross-sectional area of the upstream opening; is the cross-sectional area of the downstream opening; is the discharge coefficient of the upstream opening; and is the discharge coefficient of the downstream opening.

For rooms with single opening, the calculation of ventilation rate is more complicated than cross ventilation due to the bi-directional flow and strong turbulent effect. The ventilation rate for single-sided ventilation can be accurately predicted by combining different models for mean flow, pulsating flow and eddy penetration. [13] The mean flow rate for single-sided ventilation is determined by:

where

l = width of the window;

h = elevation of the top edge of the window;

z0 = elevation of neural level (where inside and outside pressure balance);

zref = reference elevation where the wind velocity is measured (at 10 m) and

= mean wind velocity at the reference elevation.

As observed in the equation (1), the air exchange depends linearly on the wind speed in the urban place where the architectural project will be built. CFD (Computational Fluid Dynamics) tools and zonal modelings are usually used to design naturally ventilated buildings. Windcatchers can assist wind-driven ventilation by guiding air in and out of structures.

See also

Related Research Articles

<span class="mw-page-title-main">Convection</span> Fluid flow that occurs due to heterogeneous fluid properties and body forces

Convection is single or multiphase fluid flow that occurs spontaneously due to the combined effects of material property heterogeneity and body forces on a fluid, most commonly density and gravity. When the cause of the convection is unspecified, convection due to the effects of thermal expansion and buoyancy can be assumed. Convection may also take place in soft solids or mixtures where particles can flow.

<span class="mw-page-title-main">Heating, ventilation, and air conditioning</span> Technology of indoor and vehicular environmental comfort

Heating, ventilation, and air conditioning (HVAC) is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. "Refrigeration" is sometimes added to the field's abbreviation as HVAC&R or HVACR, or "ventilation" is dropped, as in HACR.

A chimney is an architectural ventilation structure made of masonry, clay or metal that isolates hot toxic exhaust gases or smoke produced by a boiler, stove, furnace, incinerator, or fireplace from human living areas. Chimneys are typically vertical, or as near as possible to vertical, to ensure that the gases flow smoothly, drawing air into the combustion in what is known as the stack, or chimney effect. The space inside a chimney is called the flue. Chimneys are adjacent to large industrial refineries, fossil fuel combustion facilities or part of buildings, steam locomotives and ships.

<span class="mw-page-title-main">Ventilation (architecture)</span> Intentional introduction of outside air into a space

Ventilation is the intentional introduction of outdoor air into a space. Ventilation is mainly used to control indoor air quality by diluting and displacing indoor pollutants; it can also be used to control indoor temperature, humidity, and air motion to benefit thermal comfort, satisfaction with other aspects of the indoor environment, or other objectives.

<span class="mw-page-title-main">Blower door</span>

A blower door is a machine used to perform a building air leakage test. It can also be used to measure airflow between building zones, to test ductwork airtightness and to help physically locate air leakage sites in the building envelope.

A solar chimney – often referred to as a thermal chimney – is a way of improving the natural ventilation of buildings by using convection of air heated by passive solar energy. A simple description of a solar chimney is that of a vertical shaft utilizing solar energy to enhance the natural stack ventilation through a building.

<i>Tablinum</i> Room between the peristyle and atrium in Roman home architecture

In Roman architecture, a tablinum was a room generally situated on one side of the atrium and opposite to the entrance; it opened in the rear onto the peristyle, with either a large window or only an anteroom or curtain. The walls were richly decorated with fresco pictures, and busts of the family were arranged on pedestals on the two sides of the room.

<span class="mw-page-title-main">Windcatcher</span> Architectural element for creating a draft

A windcatcher, wind tower, or wind scoop is a traditional architectural element, originated in Iran (Persia), used to create cross ventilation and passive cooling in buildings. Windcatchers come in various designs, depending on whether local prevailing winds are unidirectional, bidirectional, or multidirectional, on how they change with altitude, on the daily temperature cycle, on humidity, and on how much dust needs to be removed. Despite the name, windcatchers can also function without wind.

<span class="mw-page-title-main">Eastgate Centre, Harare</span> Zimbabwean shopping and office complex

The Eastgate Centre is a shopping centre and office block in central Harare, Zimbabwe, designed by Mick Pearce. Designed to be ventilated and cooled by entirely natural means, it was probably the first building in the world to use natural cooling to this level of sophistication. It opened in 1996 on Robert Mugabe Avenue and Second Street, and provides 5,600 m² of retail space, 26,000 m² of office space and parking for 450 cars.

Ventilation is a part of structural firefighting tactics, and involves the expulsion of heat and smoke from a burning building, permitting the firefighters to more easily and safely find trapped individuals and attack the fire. If a large fire is not properly ventilated, it is much harder to fight, and can build up enough poorly burned smoke to create a smoke explosion or enough heat to create a flashover. Poorly placed or timed ventilation can increase the fire's air supply, causing it to grow and spread rapidly. Flashover from inadequate ventilation can cause the temperature inside the building to peak at over 1,000 °C (1,830 °F).

The stack effect or chimney effect is the movement of air into and out of buildings through unsealed openings, chimneys, flue-gas stacks, or other containers, resulting from air buoyancy. Buoyancy occurs due to a difference in indoor-to-outdoor air density resulting from temperature and moisture differences. The result is either a positive or negative buoyancy force. The greater the thermal difference and the height of the structure, the greater the buoyancy force, and thus the stack effect. The stack effect helps drive natural ventilation, air infiltration, and fires.

<span class="mw-page-title-main">Flue-gas stack</span> Stack

A flue-gas stack, also known as a smoke stack, chimney stack or simply as a stack, is a type of chimney, a vertical pipe, channel or similar structure through, which combustion product gases called flue gases are exhausted to the outside air. Flue gases are produced when coal, oil, natural gas, wood or any other fuel is combusted in an industrial furnace, a power plant's steam-generating boiler, or other large combustion device. Flue gas is usually composed of carbon dioxide (CO2) and water vapor, as well as nitrogen and excess oxygen remaining from the intake combustion air. It also contains a small percentage of pollutants such as particulate matter, carbon monoxide, nitrogen oxides and sulfur oxides. The flue gas stacks are often quite tall, up to 420 metres (1,380 ft), to increase the stack effect and dispersion of pollutants.

<span class="mw-page-title-main">Passive cooling</span> Building design that reduces inside temperatures without air conditioning

Passive cooling is a building design approach that focuses on heat gain control and heat dissipation in a building in order to improve the indoor thermal comfort with low or no energy consumption. This approach works either by preventing heat from entering the interior or by removing heat from the building.

<span class="mw-page-title-main">Passive ventilation</span> Ventilation without use of mechanical systems

Passive ventilation is the process of supplying air to and removing air from an indoor space without using mechanical systems. It refers to the flow of external air to an indoor space as a result of pressure differences arising from natural forces.

<span class="mw-page-title-main">Fan (machine)</span> Machine used to produce air flow

A fan is a powered machine used to create a flow of air. A fan consists of a rotating arrangement of vanes or blades, generally made of wood, plastic, or metal, which act on the air. The rotating assembly of blades and hub is known as an impeller, rotor, or runner. Usually, it is contained within some form of housing, or case. This may direct the airflow, or increase safety by preventing objects from contacting the fan blades. Most fans are powered by electric motors, but other sources of power may be used, including hydraulic motors, handcranks, and internal combustion engines.

<span class="mw-page-title-main">Rainscreen</span>

A rainscreen is an exterior wall detail where the siding stands off from the moisture-resistant surface of an air/water barrier applied to the sheathing to create a capillary break and to allow drainage and evaporation. The rainscreen is the cladding or siding itself but the term rainscreen implies a system of building. Ideally the rainscreen prevents the wall air/water barrier from getting wet but because of cladding attachments and penetrations water is likely to reach this point, and hence materials are selected to be moisture tolerant and integrated with flashing. In some cases a rainscreen wall is called a pressure-equalized rainscreen wall where the ventilation openings are large enough for the air pressure to nearly equalize on both sides of the rain screen, but this name has been criticized as being redundant and is only useful to scientists and engineers.

Dynamic insulation is a form of insulation where cool outside air flowing through the thermal insulation in the envelope of a building will pick up heat from the insulation fibres. Buildings can be designed to exploit this to reduce the transmission heat loss (U-value) and to provide pre-warmed, draft free air to interior spaces. This is known as dynamic insulation since the U-value is no longer constant for a given wall or roof construction but varies with the speed of the air flowing through the insulation. Dynamic insulation is different from breathing walls. The positive aspects of dynamic insulation need to be weighed against the more conventional approach to building design which is to create an airtight envelope and provide appropriate ventilation using either natural ventilation or mechanical ventilation with heat recovery. The air-tight approach to building envelope design, unlike dynamic insulation, results in a building envelope that provides a consistent performance in terms of heat loss and risk of interstitial condensation that is independent of wind speed and direction. Under certain wind conditions a dynamically insulated building can have a higher heat transmission loss than an air-tight building with the same thickness of insulation. Often the air enters at about 15 °C.

Airflow, or air flow, is the movement of air. The primary cause of airflow is the existence of air. Air behaves in a fluid manner, meaning particles naturally flow from areas of higher pressure to those where the pressure is lower. Atmospheric air pressure is directly related to altitude, temperature, and composition.

CFD stands for computational fluid dynamics. As per this technique, the governing differential equations of a flow system or thermal system are known in the form of Navier–Stokes equations, thermal energy equation and species equation with an appropriate equation of state. In the past few years, CFD has been playing an increasingly important role in building design, following its continuing development for over a quarter of a century. The information provided by CFD can be used to analyse the impact of building exhausts to the environment, to predict smoke and fire risks in buildings, to quantify indoor environment quality, and to design natural ventilation systems.

Building airtightness can be defined as the resistance to inward or outward air leakage through unintentional leakage points or areas in the building envelope. This air leakage is driven by differential pressures across the building envelope due to the combined effects of stack, external wind and mechanical ventilation systems.

References

  1. 1 2 3 Wind ventilation and cross ventilation Connection Magazines
  2. Kosutova, Katarina; Van Hooff, Twan; Vanderwel, Christina; Blocken, Bert; Hensen, Jan (2019). "Cross-ventilation in a generic isolated building equipped with louvers: Wind-tunnel experiments and CFD simulations" (PDF). Building and Environment. 154: 263–280. Bibcode:2019BuEnv.154..263K. doi: 10.1016/j.buildenv.2019.03.019 . S2CID   116029282.
  3. Basics of Natural Ventilation CoolVent
  4. Cross Ventilation, the Chimney Effect and Other Concepts of Natural Ventilation ArchDaily 2008-2022
  5. Cross ventilation Designing Buildings Ltd. 2022
  6. The Importance of Cross-ventilation HACK architecture | Newcastle Architects
  7. CROSS VENTILATION 2030 PALETTE®
  8. Natural Ventilation Strategies Window Master
  9. Zhou, Junli; Hua, Yong; Xiao, Yuan; Ye, Cheng; Yang, Wei (2021). "Analysis of Ventilation Efficiency and Effective Ventilation Flow Rate for Wind-driven Single-sided Ventilation Buildings". Aerosol and Air Quality Research. 21 (5): 200383. doi:10.4209/aaqr.200383. hdl: 11343/280700 . S2CID   230593586.
  10. World Health Organization (2021). Roadmap to improve and ensure good indoor ventilation in the context of COVID-19 (PDF). World Health Organization. Retrieved 10 August 2023.
  11. ENERGY EFFICIENCY MEASURES - HME09 – NATURAL VENTILATION International Finance Corporation
  12. ASHRAE Handbook. Atlanta, GA: American Society of Heating, Refrigerating and Air Conditioning Engineers. 2009.
  13. Wang, Haojie; Chen, Qingyan (2012). "A New Empirical Model for Predicting Single-Sided, Wind-Driven Natural Ventilation in Buildings". Energy and Buildings. 54: 386–394. Bibcode:2012EneBu..54..386W. doi:10.1016/j.enbuild.2012.07.028.