ASHRAE Handbook

Last updated

The ASHRAE Handbook is the four-volume flagship publication of the nonprofit technical organization ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers [lower-alpha 1] ). This Handbook is considered the most comprehensive and authoritative repository of practical knowledge on the various topics that form the field of heating, ventilation, air-conditioning, and refrigeration (HVAC&R). [lower-alpha 2]

Contents

The four volumes are Fundamentals, Refrigeration, HVAC Applications ("Applications"), and HVAC Systems and Equipment ("Systems and Equipment"). Members of ASHRAE receive the current volume, in both print and CD-ROM form, each year as a basic membership benefit. An enhanced electronic version, known as ASHRAE Handbook Online is a web-based version updated annually that contains the four latest volumes as well as extra content such as calculations, demonstration videos, and spreadsheets. The various versions of the Handbook are typically available to the public via technical, and other, libraries and bookstores.[ citation needed ]

History

The ASHRAE Handbook has had a variety of titles. [5] It began in 1922 as the ASH&VE Guide. In 1973 it became the ASHRAE Handbook, and in 1985 separate publication of inch-pound (I-P) and international system (SI) units versions of the volumes began. The current publisher of record is W. Stephen Comstock, and the Editor is Mark S. Owen. The Handbook is published by ASHRAE from its headquarters in Atlanta, Georgia.

Review and Revision

The Handbook's content is created and modified by volunteers via ASHRAE's many Technical Committees (TCs), and then edited and formatted by professional staff at ASHRAE. For example, three chapters, in three different volumes, are maintained by TC 5.3, Room Air Distribution. Each chapter within a particular volume is reviewed and revised in a repeating four-year cycle; one volume is printed each year. [6] In the summer of 2017 the new Fundamentals' volume was released. ASHRAE's Handbook Committee maintains an Authors and Revisers Guide, which can be obtained freely via the Handbook portion of the ASHRAE Web site.

While each new or revised chapter manuscript is to be reviewed for technical content by each TC voting and corresponding member before publication, there are often many other pre- and post-publication reviewers. For example, members of the Society's Handbook Committee and the College of Fellows [7] review chapters each year. Reviews, from basic comments to detailed new content, are encouraged from all users of the Handbook and may be submitted through an online commenting system.

Notes

  1. About its name, ASHRAE says the following: 'In 2012, as part of a rebranding, ASHRAE began doing business as “ASHRAE” vs. using its full legal name of the American Society of Heating, Refrigerating and Air-Conditioning Engineers. Use of ASHRAE reflects the Society’s worldwide membership and that services will continue evolving globally.' [1]
  2. Here is how some other sources have characterized the Handbook:
    'The four-volume ASHRAE Handbook… provides the most comprehensive and authoritative reference on HVAC systems for buildings.' [2]
    'ASHRAE HANDBOOK & Product Directory… has been known as the “Bible" of the industry for over fifty years.' [3]
    'The standard method for determining heat losses from a structure, at least in the United States, is to consult the bible for heat flow calculations — the ASHRAE Fundamentals.' [4] :91
    'It is rare to use the analysis just presented to determine the heat loss through glass. Instead, the empirically based tables and formulae given in the ASHRAE Fundamentals are most often consulted.' [4] :95
    'The definitive works on the thermal resistance of air spaces can be found in ASHRAE Fundamentals.' [4] :96
    'The heat loss through a window is commonly determined from the conductance of that window, and the authority for this, at least in the United States, is ASHRAE Fundamentals.' [4] :103
    'ASHRAE is a leading authority on heat and moisture transfer, and air infiltration in a structure. Its Handbook of Fundamentals is considered by many to be the best source of technical information.' [4] :156

Related Research Articles

The British thermal unit is a measure of heat, which is a form of energy. It was originally defined as the amount of heat required to raise the temperature of one pound of water by one degree Fahrenheit. It is also part of the United States customary units. The SI unit for energy is the joule (J); one BTU equals about 1,055 J.

<span class="mw-page-title-main">Heating, ventilation, and air conditioning</span> Technology of indoor and vehicular environmental comfort

Heating, ventilation, and air conditioning (HVAC) is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. "Refrigeration" is sometimes added to the field's abbreviation as HVAC&R or HVACR, or "ventilation" is dropped, as in HACR.

Cooling is removal of heat, usually resulting in a lower temperature and/or phase change. Temperature lowering achieved by any other means may also be called cooling. The transfer of thermal energy may occur via thermal radiation, heat conduction or convection. Examples can be as simple as reducing temperature of a coffee.

Variable air volume (VAV) is a type of heating, ventilating, and/or air-conditioning (HVAC) system. Unlike constant air volume (CAV) systems, which supply a constant airflow at a variable temperature, VAV systems vary the airflow at a constant or varying temperature. The advantages of VAV systems over constant-volume systems include more precise temperature control, reduced compressor wear, lower energy consumption by system fans, less fan noise, and additional passive dehumidification.

<span class="mw-page-title-main">Underfloor heating</span> Form of central heating and cooling

Underfloor heating and cooling is a form of central heating and cooling that achieves indoor climate control for thermal comfort using hydronic or electrical heating elements embedded in a floor. Heating is achieved by conduction, radiation and convection. Use of underfloor heating dates back to the Neoglacial and Neolithic periods.

<span class="mw-page-title-main">Energy recovery ventilation</span> Uses the energy in air exhausted from a building to treat the incoming air

Energy recovery ventilation (ERV) is the energy recovery process in residential and commercial HVAC systems that exchanges the energy contained in normally exhausted air of a building or conditioned space, using it to treat (precondition) the incoming outdoor ventilation air. The specific equipment involved may be called an Energy Recovery Ventilator, also commonly referred to simply as an ERV.

Infiltration is the unintentional or accidental introduction of outside air into a building, typically through cracks in the building envelope and through use of doors for passage. Infiltration is sometimes called air leakage. The leakage of room air out of a building, intentionally or not, is called exfiltration. Infiltration is caused by wind, negative pressurization of the building, and by air buoyancy forces known commonly as the stack effect.

A chilled beam is a type of radiation/convection HVAC system designed to heat and cool large buildings through the use of water. This method removes most of the zone sensible local heat gains and allows the flow rate of pre-conditioned air from the air handling unit to be reduced, lowering by 60% to 80% the ducted design airflow rate and the equipment capacity requirements. There are two types of chilled beams, a Passive Chilled Beam (PCB) and an Active Chilled Beam (ACB). They both consist of pipes of water (fin-and-tube) that pass through a heat exchanger contained in a case suspended from, or recessed in, the ceiling. As the beam cools the air around it, the air becomes denser and falls to the floor. It is replaced by warmer air moving up from below, causing a constant passive air movement called convection, to cool the room. The active beam consists of air duct connections, induction nozzles, hydronic heat transfer coils, supply outlets and induced air inlets. It contains an integral air supply that passes through nozzles, and induces air from the room to the cooling coil. For this reason, it has a better cooling capacity than the passive beam. Instead, the passive beam provides space cooling without the use of a fan and it is mainly done by convection. Passive beams can be either exposed or recessed. The passive approach can provide higher thermal comfort levels, while the active approach uses the momentum of ventilation air that enters at relatively high velocity to induce the circulation of room air through the unit. A chilled beam is similar in appearance to a VRF unit.

Wrightsoft is a software development firm for heating, ventilation, and air conditioning (HVAC). Established in 1985, Wrightsoft has served residential, commercial, and educational markets by providing HVAC design, specification, and sales software. Wrightsoft is headquartered in Lexington, Massachusetts, USA.

HVAC is a major sub discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other factors such as installation cost, ease of maintenance, and energy efficiency. The discipline of HVAC includes a large number of specialized terms and acronyms, many of which are summarized in this glossary.

<span class="mw-page-title-main">Essam E. Khalil</span> Egyptian Mechanical Engineer (born 1948)

Essam Eldin Khalil Hassan Khalil is an Egyptian Mechanical Engineer. Khalil is a professor in the mechanical power department at Cairo University. He is the author and co-author of several international researches in HVAC field. He has many years of experience in delivering courses in air-conditioning to University, college students, to building managers and maintenance staff in both the industrial and commercial sectors in Egypt, the Arabian countries and worldwide. He has been selected by various universities and international organisations to lecture to graduate and post graduate level engineers, managers, supervisors and operating personnel on the subjects of HVAC design and optimisation, HVAC system management, energy utilization, waste heat recovery, plant management and other related subjects.

<span class="mw-page-title-main">Underfloor air distribution</span>

Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system. UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets, located at or near floor level within the occupied space. Air returns from the room at ceiling level or the maximum allowable height above the occupied zone.

<span class="mw-page-title-main">Dedicated outdoor air system</span>

A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning (HVAC) system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the loads generated by indoor/process sources and those that pass through the building enclosure.

ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings. The original standard, ASHRAE 90, was published in 1975. There have been multiple editions to it since. In 1999 the ASHRAE Board of Directors voted to place the standard on continuous maintenance, based on rapid changes in energy technology and energy prices. This allows it to be updated multiple times in a year. The standard was renamed ASHRAE 90.1 in 2001. It has since been updated in 2004, 2007, 2010, 2013, 2016, and 2019 to reflect newer and more efficient technologies.

<span class="mw-page-title-main">International Institute of Refrigeration</span> Company

The International Institute of Refrigeration (IIR), is an independent intergovernmental science and technology-based organization which promotes knowledge of refrigeration and associated technologies and applications on a global scale that improve quality of life in a cost-effective and environmentally sustainable manner, including:

<span class="mw-page-title-main">Radiant heating and cooling</span> Category of HVAC technologies

Radiant heating and cooling is a category of HVAC technologies that exchange heat by both convection and radiation with the environments they are designed to heat or cool. There are many subcategories of radiant heating and cooling, including: "radiant ceiling panels", "embedded surface systems", "thermally active building systems", and infrared heaters. According to some definitions, a technology is only included in this category if radiation comprises more than 50% of its heat exchange with the environment; therefore technologies such as radiators and chilled beams are usually not considered radiant heating or cooling. Within this category, it is practical to distinguish between high temperature radiant heating, and radiant heating or cooling with more moderate source temperatures. This article mainly addresses radiant heating and cooling with moderate source temperatures, used to heat or cool indoor environments. Moderate temperature radiant heating and cooling is usually composed of relatively large surfaces that are internally heated or cooled using hydronic or electrical sources. For high temperature indoor or outdoor radiant heating, see: Infrared heater. For snow melt applications see: Snowmelt system.

<span class="mw-page-title-main">ASHRAE</span> American HVAC professional association

The American Society of Heating, Refrigerating and Air-Conditioning Engineers is an American professional association seeking to advance heating, ventilation, air conditioning and refrigeration (HVAC&R) systems design and construction. ASHRAE has over 50,000 members in more than 130 countries worldwide.

The Institute of Refrigeration is an organisation in the UK that supports the refrigeration and air-conditioning industry.

Ductwork airtightness can be defined as the resistance to inward or outward air leakage through the ductwork envelope. This air leakage is driven by differential pressures across the ductwork envelope due to the combined effects of stack and fan operation.

Cooling load is the rate at which sensible and latent heat must be removed from the space to maintain a constant space dry-bulb air temperature and humidity. Sensible heat into the space causes its air temperature to rise while latent heat is associated with the rise of the moisture content in the space. The building design, internal equipment, occupants, and outdoor weather conditions may affect the cooling load in a building using different heat transfer mechanisms. The SI units are watts.

References

  1. "About ASHRAE" . Retrieved 2020-03-04.
  2. Turner, Wayne C.; Doty, Steve (2007). Energy Management Handbook (Sixth ed.). Lilburn, GA: The Fairmont Press, Inc. ISBN   978-0-88173-542-0.
  3. United States Congress, House Committee on Interstate and Foreign Commerce, Subcommittee on Oversight and Investigations (September 21, 1978). Consumer protection issues in the development of solar energy. Washington, DC: United States Government Printing Office.{{cite book}}: CS1 maint: multiple names: authors list (link)
  4. 1 2 3 4 5 Parkin, Robert E. (2017). Building-Integrated Solar Energy Systems. Boca Raton, FL: CRC Press. ISBN   978-1-4987-2776-1.
  5. "The ASHRAE Centennial: 100 Years of Progress", ASHRAE Historical Committee, 1994
  6. "ASHRAE Handbook Authors and Revisers Guide", ASHRAE Inc., August 2007
  7. "Handbook". Archived from the original on 2008-07-04. Retrieved 2008-05-21. , accessed May 21, 2008