Section 608

Last updated

Section 608 (together with Section 609, which covers motor vehicles) of the Clean Air Act serves as the main form of occupational licensure for technicians in the heating, ventilation, and air conditioning (HVAC) industry in the United States. [1] The law requires that all persons who maintain, service, repair or dispose of appliances that contain regulated refrigerants be certified in proper refrigerant handling techniques. [2] The regulatory program helps to minimize the release of refrigerants, and in particular ozone depleting refrigerants such as chlorofluorocarbons and hydrofluorocarbons, as well as other regulated refrigerants as determined by Section 612. The licensure program complies with the requirements under the Montreal Protocol. The Environmental Protection Agency (EPA) published implementing regulations at 40 CFR Part 82. [3]

Contents

Scope

There are four categories of certification:

TypeApplication
IPersons who maintain, service or repair small appliances with less than 5 lbs of refrigerant.
IIPersons who maintain, service, repair or dispose of high pressure appliances, except for small appliances.
IIIPersons who maintain, service, repair, or dispose of low pressure appliances.
UniversalPersons who maintain, service, repair, or dispose of any appliance in categories of types I, II, or III.

A technician with the required level of certification may also legally purchase regulated refrigerants. And technicians who violate the Clean Air Act provisions may be fined, lose their certification, and may be required to appear in Federal court. [4]

Provisions

In general, along with general enforcement provisions, section 608 manages the following regulatory requirements:

Recovery level

For Type I systems the main requirement is to remove 80% of the refrigerant if the appliance's compressor is not running and 90% if running and evacuate to a 4 inch Hg vacuum.

For Type II or Type III applications, the appliance must be evacuated to the following levels for device manufactured after November 15, 1993 in order to recover the refrigerant

ApplicationRequired Evacuation
Very high pressure0"Hg
High pressure w/<200 lbs of refrigerant0"Hg
High pressure w/>=200 lbs of refrigerant10"Hg
Medium pressure w/<200 lbs of refrigerant10"Hg
Medium pressure w/>=200 lbs of refrigerant15"Hg
Low pressure (Type III)25mm Hg absolute

[6]

Where pressure classification of the refrigerant is defined by the refrigerant's pressure at 104F as

TypePressure
Very High PressureAbove 355 psia
High PressureBetween 170 and 355 psia
Medium PressureBetween 45 psia and 170 psia
Low PressureBelow 45 psia

[7]

Recording Requirements

For systems containing 50 lbs or more of refrigerant, for each service, the owner must be supplied with information of:

And such records must be held for 3 years. [8]

Additionally, if an appliance leaks more than 125% of refrigerant, it must be reported to the EPA. [9]

Leak Repair Requirements

Leaks must be repaired in systems with greater than 50 lbs of refrigerant if the leak rate exceeds

ApplicationAnnual Leak Rate %
Industrial Process Refrigeration30%
Commercial Refrigeration20%
Comfort/Residential Cooling10%

In which case, they must be repaired within 30 days/120 if industrial process shutdown is required. An initial verification test must then be done within 30/120 days, and then a follow-up test within 10 days of that. There are additional clauses for extensions if needed.

If the leak is not to be repaired, there must be a plan to retire or retrofit the appliance within 30 days, to be completed within one year. [10]

If more than a year is required, a report must be submitted, which must include:

Leak Inspection Regulations

Additional leak inspection frequencies following a leak must regard the following until the leak rate is within acceptable levels:

System SizeApplicationFrequency
>=500lbsIndustrial Process and Commercial RefrigerationEvery 3 months for a year.
<500 lbs and >=50lbsIndustrial Process and Commercial RefrigerationAnnually
--Comfort/Residential CoolingAnnually

These leak inspections may be bypassed if the system is installed with an automatic leak detection system. [11]

Credentialing and Exams

EPA regulations require the test to be a "closed book" proctored exam. The only outside materials allowed are a temperature / pressure chart, scratch paper and a calculator. The certification exam contains 4 sections: Core, Type I, Type II, and Type III. Each section contains 25 multiple choice questions. The technician must achieve a passing score of 70% in each Type in which they are to be certified. All technicians must pass the CORE section before receiving any certification. A technician seeking certification must correctly answer 18 out of 25 questions on the CORE and at least one other section of the exam. A technician seeking Universal certification must correctly answer 18 out of 25 questions on each section of the exam.

In addition to covering EPA (in particular, Section 608) regulations, the exam also covers basic safety and occupational practices, along with fundamental concepts of stratospheric ozone protection (which are typically part of the Core exam). [2]

Many universities and colleges also have associate degrees and apprenticeship programs that teach HVAC fundamentals along with providing EPA examinations. [12] [13] [14]

See also

Related Research Articles

<span class="mw-page-title-main">Heating, ventilation, and air conditioning</span> Technology of indoor and vehicular environmental comfort

Heating, ventilation, and air conditioning (HVAC) is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. "Refrigeration" is sometimes added to the field's abbreviation as HVAC&R or HVACR, or "ventilation" is dropped, as in HACR.

<span class="mw-page-title-main">Refrigerant</span> Substance in a refrigeration cycle

A refrigerant is a working fluid used in the refrigeration cycle of air conditioning systems and heat pumps where in most cases they undergo a repeated phase transition from a liquid to a gas and back again. Refrigerants are heavily regulated due to their toxicity, flammability and the contribution of CFC and HCFC refrigerants to ozone depletion and that of HFC refrigerants to climate change.

<span class="mw-page-title-main">Chiller</span> Machine that removes heat from a liquid coolant via vapor compression

A chiller is a machine that removes heat from a liquid coolant via a vapor-compression, adsorption refrigeration, or absorption refrigeration cycles. This liquid can then be circulated through a heat exchanger to cool equipment, or another process stream. As a necessary by-product, refrigeration creates waste heat that must be exhausted to ambience, or for greater efficiency, recovered for heating purposes. Vapor compression chillers may use any of a number of different types of compressors. Most common today are the hermetic scroll, semi-hermetic screw, or centrifugal compressors. The condensing side of the chiller can be either air or water cooled. Even when liquid cooled, the chiller is often cooled by an induced or forced draft cooling tower. Absorption and adsorption chillers require a heat source to function.

Propane refrigeration is a type of compression refrigeration. Propane (R290) has been used successfully in industrial refrigeration for many years, and is emerging as an increasingly viable alternative for homes and businesses. Propane's operating pressures and temperatures are well suited for use in air conditioning equipment, but because of propane’s flammability, great care is required in the manufacture, installation and servicing of equipment that uses it as a refrigerant.

Chlorodifluoromethane or difluoromonochloromethane is a hydrochlorofluorocarbon (HCFC). This colorless gas is better known as HCFC-22, or R-22, or CHClF
2
. It was commonly used as a propellant and refrigerant. These applications were phased out under the Montreal Protocol in developed countries in 2020 due to the compound's ozone depletion potential (ODP) and high global warming potential (GWP), and in developing countries this process will be completed by 2030. R-22 is a versatile intermediate in industrial organofluorine chemistry, e.g. as a precursor to tetrafluoroethylene.

<span class="mw-page-title-main">Icemaker</span>

An icemaker, ice generator, or ice machine may refer to either a consumer device for making ice, found inside a home freezer; a stand-alone appliance for making ice, or an industrial machine for making ice on a large scale. The term "ice machine" usually refers to the stand-alone appliance.

<span class="mw-page-title-main">Vapor-compression refrigeration</span> Refrigeration process

Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles. It is also used in domestic and commercial refrigerators, large-scale warehouses for chilled or frozen storage of foods and meats, refrigerated trucks and railroad cars, and a host of other commercial and industrial services. Oil refineries, petrochemical and chemical processing plants, and natural gas processing plants are among the many types of industrial plants that often utilize large vapor-compression refrigeration systems. Cascade refrigeration systems may also be implemented using two compressors.

Natural refrigerants are substances that serve as refrigerants in refrigeration systems. They are alternatives to synthetic refrigerants such as chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), and hydrofluorocarbon (HFC) based refrigerants. Unlike other refrigerants, natural refrigerants are non-synthetic and can be found in nature. The most prominent of these include various natural hydrocarbons, carbon dioxide, ammonia, and water. Natural refrigerants are preferred to their synthetic counterparts for their higher degrees of sustainability. With the current technologies available, almost 75 percent of the refrigeration and air conditioning sector has the potential to be converted to natural refrigerants.

In the United States, the state governments have jurisdiction for issuing most professional licenses to individuals and corporations. In areas that naturally cross states' borders, the national government may be the issuer. Thus the Federal Aviation Administration certificates pilots and other aviation related professionals, such as mechanics and instructors. The Federal Communications Commission certifies persons operating and repairing amateur and many commercial radio transmitters. The Environmental Protection Agency requires that technicians recycling Freon be examined. In many of these areas the federal government approves organizations to test and certify applicants who meet its standards.

<span class="mw-page-title-main">EcoCute</span>

The EcoCute is an energy-efficient electric heat pump, water heating and supply system that uses heat extracted from the air to heat water for domestic, industrial and commercial use. Instead of the more conventional ammonia or haloalkane gases, EcoCute uses supercritical carbon dioxide as a refrigerant. The technology offers a means of energy conservation and reduces the emission of greenhouse gas.

<span class="mw-page-title-main">Reversing valve</span>

A reversing valve is a type of valve and is a component in a heat pump, that changes the direction of refrigerant flow. By reversing the flow of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa. This allows a residence or facility to be heated and cooled by a single piece of equipment, by the same means, and with the same hardware.

Refrigerant reclamation is the act of processing used refrigerant gas which has previously been used in some type of refrigeration loop such that it meets specifications for new refrigerant gas. In the United States, the Section 608 of the Clean Air Act of 1990 requires that used refrigerant be processed by a certified reclaimer, which must be licensed by the United States Environmental Protection Agency (EPA), and the material must be recovered and delivered to the reclaimer by EPA-certified technicians.

<span class="mw-page-title-main">Freeze stat</span> Temperature sensing device

A freeze stat is a temperature sensing device for HVAC that monitors a heat exchanger to prevent its coils from freezing. Freeze stats can be used on both refrigerant-to-air, and refrigerant-to-liquid type heat exchangers and serve different purposes with similar goals for each.

The Air Conditioning, Heating, and Refrigeration Institute (AHRI), formed in 2008 by a merger of the Air-Conditioning and Refrigeration Institute (ARI) and the Gas Appliance Manufacturers Association (GAMA), is a North American trade association of manufacturers of air conditioning, heating, and commercial refrigeration equipment.

HVAC is a major sub discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other factors such as installation cost, ease of maintenance, and energy efficiency. The discipline of HVAC includes a large number of specialized terms and acronyms, many of which are summarized in this glossary.

Daikin Applied Americas is a corporation that designs, manufacturers and sells heating, ventilation, and air conditioning (HVAC) products, systems, parts and services for commercial buildings. Since 2006, McQuay has been a subsidiary of Daikin Industries, Ltd. McQuay world headquarters are located in Minneapolis, Minnesota, United States. Products are sold by a global network of sales representatives and distributors.

Variable refrigerant flow (VRF), also known as variable refrigerant volume (VRV), is an HVAC technology invented by Daikin Industries, Ltd. in 1982. Like ductless minisplits, VRFs use refrigerant as the cooling and heating medium. This refrigerant is conditioned by one or more condensing units, and is circulated within the building to multiple indoor units. VRF systems, unlike conventional chiller-based systems, allow for varying degrees of cooling in more specific areas, may supply hot water in a heat recovery configuration without affecting efficiency, and switch to heating mode during winter without additional equipment, all of which may allow for reduced energy consumption. Also, air handlers and large ducts are not used which can reduce the height above a dropped ceiling as well as structural impact as VRF uses smaller penetrations for refrigerant pipes instead of ducts.

An inverter compressor is a gas compressor that is operated with an inverter.

The Significant New Alternatives Policy is a program of the EPA to determine acceptable chemical substitutes, and establish which are prohibited or regulated by the EPA. It also establishes a program by which new alternatives may be accepted, and promulgates timelines to the industry regarding phase-outs of substitutes.

References

  1. United States. Clean Air Act. "National recycling and emission reduction program." 42 U.S.C. 7671(g).
  2. 1 2 "Section 608 Technician Certification". EPA. 2022-11-02.
  3. U.S. Environmental Protection Agency (EPA), Washington, D.C. Code of Federal Regulations, Title 40. "Part 82: Protection of Stratospheric Ozone. Subpart I: Ban on Refrigeration and Air-Conditioning Appliances Containing HCFCs."
  4. 1 2 "EPA's Refrigerant Management Program: Questions and Answers for Section 608 Certified Technicians". 15 May 2018.
  5. "Section 608 of the Clean Air Act: Stationary Refrigeration and Air Conditioning" (PDF). EPA. EPA 430-F-18-001.
  6. "§ 82.156 Proper evacuation of refrigerant from appliances". eCFR. EPA.
  7. "§ 82.152 Definitions". eCFR. EPA.
  8. "§ 82.166 Reporting and recordkeeping requirements for leak repair". eCFR. EPA.
  9. "§ 82.157 Appliance maintenance and leak repair". eCFR. EPA.
  10. "§ 82.157 Appliance maintenance and leak repair". eCFR. EPA.
  11. "§ 82.157 Appliance maintenance and leak repair". eCFR. EPA.
  12. "Heating, Ventilating, Air Conditioning and Refrigeration". Big Rapids, MI: Ferris State University.
  13. "Heating, Air Conditioning & Refrigeration". Des Moines Area Community College. Retrieved 2023-03-20.
  14. "Section 608 Technician Certification Programs". EPA. 2023-02-22.