Fiber Distributed Data Interface (FDDI) is a standard for data transmission in a local area network. It uses optical fiber as its standard underlying physical medium.
It was also later specified to use copper cable, in which case it may be called CDDI (Copper Distributed Data Interface), standardized as TP-PMD (Twisted-Pair Physical Medium-Dependent), also referred to as TP-DDI (Twisted-Pair Distributed Data Interface).
FDDI was effectively made obsolete in local networks by Fast Ethernet which offered the same 100 Mbit/s speeds, but at a much lower cost and, from 1998 on, by Gigabit Ethernet due to its speed, even lower cost, and ubiquity. [1]
FDDI provides a 100 Mbit/s optical standard for data transmission in local area network that can extend in length up to 200 kilometers (120 mi). [2] Although FDDI logical topology is a ring-based token network, it did not use the IEEE 802.5 Token Ring protocol as its basis; instead, its protocol was derived from the IEEE 802.4 token bus timed token protocol. In addition to covering large geographical areas, FDDI local area networks can support thousands of users. FDDI offers both a Dual-Attached Station (DAS), counter-rotating token ring topology and a Single-Attached Station (SAS), token bus passing ring topology. [3]
FDDI, as a product of American National Standards Institute X3T9.5 (now X3T12), conforms to the Open Systems Interconnection (OSI) model of functional layering using other protocols. The standards process started in the mid 1980s. [4] FDDI-II, a version of FDDI described in 1989, added circuit-switched service capability to the network so that it could also handle voice and video signals. [5] Work started to connect FDDI networks to synchronous optical networking (SONET) technology.
An FDDI network contains two rings, one as a secondary backup in case the primary ring fails. The primary ring offers up to 100 Mbit/s capacity. When a network has no requirement for the secondary ring to do backup, it can also carry data, extending capacity to 200 Mbit/s. The single ring can extend the maximum distance; a dual ring can extend 100 km (62 mi). FDDI had a larger maximum frame size (4,352 bytes) than the standard Ethernet family, which only supports a maximum frame size of 1,500 bytes, [a] allowing better effective data rates in some cases.
Designers normally constructed FDDI rings in a network topology such as a "dual ring of trees". A small number of devices, typically infrastructure devices such as routers and concentrators rather than host computers, were "dual-attached" to both rings. Host computers then connect as single-attached devices to the routers or concentrators. The dual ring in its most degenerate form simply collapses into a single device. Typically, a computer-room contained the whole dual ring, although some implementations deployed FDDI as a metropolitan area network. [6]
FDDI requires this network topology because the dual ring actually passes through each connected device and requires each such device to remain continuously operational. The standard actually allows for optical bypasses, but network engineers consider these unreliable and error-prone. Devices such as workstations and minicomputers that might not come under the control of the network managers are not suitable for connection to the dual ring.
As an alternative to using a dual-attached connection, a workstation can obtain the same degree of resilience through a dual-homed connection made simultaneously to two separate devices in the same FDDI ring. One of the connections becomes active while the other one is automatically blocked. If the first connection fails, the backup link takes over with no perceptible delay. [7]
Internet protocol suite |
---|
Application layer |
Transport layer |
Internet layer |
Link layer |
Preamble, PA | 16 bits |
---|---|
Start delimiter, SD | 8 bits |
Frame control, FC | 8 bits |
Destination address, DA | 48 bits |
Source address, SA | 48 bits |
Protocol (or packet) data unit, PDU | Up to 4478 × 8 bits |
Frame check sequence, FCS | 32 bits |
End delimiter/frame status, ED/FS | 16 bits |
The frame check sequence uses the same cyclic redundancy check as Token Ring and Ethernet.
The Internet Engineering Task Force defined a standard for transmission of the Internet Protocol (which would be the protocol data unit in this case) over FDDI. It was first proposed in June 1989 [9] and revised in 1990. [10] Some aspects of the protocol were compatible with the IEEE 802.2 standard for logical link control. For example, the 48-bit MAC addresses that became popular with the Ethernet family. Thus other protocols such as the Address Resolution Protocol (ARP) could be common as well. [10]
FDDI was considered an attractive campus backbone network technology in the early to mid 1990s since existing Ethernet networks only offered 10 Mbit/s data rates and Token Ring networks only offered 4 Mbit/s or 16 Mbit/s rates. Thus it was a relatively high-speed choice of that era, with speeds such as 100 Mbit/s. By 1994, vendors included Cisco Systems, National Semiconductor, Network Peripherals, SysKonnect (acquired by Marvell Technology Group), and 3Com. [11]
FDDI installations have largely been replaced by Ethernet deployments. [1]
FDDI standards included: [12]
Ethernet is a family of wired computer networking technologies commonly used in local area networks (LAN), metropolitan area networks (MAN) and wide area networks (WAN). It was commercially introduced in 1980 and first standardized in 1983 as IEEE 802.3. Ethernet has since been refined to support higher bit rates, a greater number of nodes, and longer link distances, but retains much backward compatibility. Over time, Ethernet has largely replaced competing wired LAN technologies such as Token Ring, FDDI and ARCNET.
IEEE 802.2 is the original name of the ISO/IEC 8802-2 standard which defines logical link control (LLC) as the upper portion of the data link layer of the OSI Model. The original standard developed by the Institute of Electrical and Electronics Engineers (IEEE) in collaboration with the American National Standards Institute (ANSI) was adopted by the International Organization for Standardization (ISO) in 1998, but it remains an integral part of the family of IEEE 802 standards for local and metropolitan networks.
A local area network (LAN) is a computer network that interconnects computers within a limited area such as a residence, school, laboratory, university campus or office building. By contrast, a wide area network (WAN) not only covers a larger geographic distance, but also generally involves leased telecommunication circuits.
Synchronous Optical Networking (SONET) and Synchronous Digital Hierarchy (SDH) are standardized protocols that transfer multiple digital bit streams synchronously over optical fiber using lasers or highly coherent light from light-emitting diodes (LEDs). At low transmission rates data can also be transferred via an electrical interface. The method was developed to replace the plesiochronous digital hierarchy (PDH) system for transporting large amounts of telephone calls and data traffic over the same fiber without the problems of synchronization.
In telecommunications, a distributed-queue dual-bus network (DQDB) is a distributed multi-access network that (a) supports integrated communications using a dual bus and distributed queuing, (b) provides access to local or metropolitan area networks, and (c) supports connectionless data transfer, connection-oriented data transfer, and isochronous communications, such as voice communications.
Network topology is the arrangement of the elements of a communication network. Network topology can be used to define or describe the arrangement of various types of telecommunication networks, including command and control radio networks, industrial fieldbusses and computer networks.
In computer networking, Fast Ethernet physical layers carry traffic at the nominal rate of 100 Mbit/s. The prior Ethernet speed was 10 Mbit/s. Of the Fast Ethernet physical layers, 100BASE-TX is by far the most common.
In the seven-layer OSI model of computer networking, the physical layer or layer 1 is the first and lowest layer: the layer most closely associated with the physical connection between devices. The physical layer provides an electrical, mechanical, and procedural interface to the transmission medium. The shapes and properties of the electrical connectors, the frequencies to transmit on, the line code to use and similar low-level parameters, are specified by the physical layer.
In IEEE 802 LAN/MAN standards, the medium access control (MAC), also called media access control, is the layer that controls the hardware responsible for interaction with the wired or wireless transmission medium. The MAC sublayer and the logical link control (LLC) sublayer together make up the data link layer. The LLC provides flow control and multiplexing for the logical link, while the MAC provides flow control and multiplexing for the transmission medium.
IEEE 802.6 is a standard governed by the ANSI for Metropolitan Area Networks (MAN). It is an improvement of an older standard which used the Fiber distributed data interface (FDDI) network structure. The FDDI-based standard failed due to its expensive implementation and lack of compatibility with current LAN standards. The IEEE 802.6 standard uses the Distributed Queue Dual Bus (DQDB) network form. This form supports 150 Mbit/s transfer rates. It consists of two unconnected unidirectional buses. DQDB is rated for a maximum of 160 km before significant signal degradation over fiberoptic cable with an optical wavelength of 1310 nm.
A ring network is a network topology in which each node connects to exactly two other nodes, forming a single continuous pathway for signals through each node – a ring. Data travels from node to node, with each node along the way handling every packet.
Open Transport Network (OTN) is a flexible private communication network based on fiber optic technology, manufactured by OTN Systems.
A computer network is a set of computers sharing resources located on or provided by network nodes. Computers use common communication protocols over digital interconnections to communicate with each other. These interconnections are made up of telecommunication network technologies based on physically wired, optical, and wireless radio-frequency methods that may be arranged in a variety of network topologies.
EtherCAT is an Ethernet-based fieldbus system developed by Beckhoff Automation. The protocol is standardized in IEC 61158 and is suitable for both hard and soft real-time computing requirements in automation technology.
The physical-layer specifications of the Ethernet family of computer network standards are published by the Institute of Electrical and Electronics Engineers (IEEE), which defines the electrical or optical properties and the transfer speed of the physical connection between a device and the network or between network devices. It is complemented by the MAC layer and the logical link layer. An implementation of a specific physical layer is commonly referred to as PHY.
Token Ring is a physical and data link layer computer networking technology used to build local area networks. It was introduced by IBM in 1984, and standardized in 1989 as IEEE 802.5. It uses a special three-byte frame called a token that is passed around a logical ring of workstations or servers. This token passing is a channel access method providing fair access for all stations, and eliminating the collisions of contention-based access methods.
Sercos III is the third generation of the Sercos interface, a standardized open digital interface for the communication between industrial controls, motion devices, input/output devices (I/O), and Ethernet nodes, such as PCs. Sercos III applies the hard real-time features of the Sercos interface to Ethernet. It is based upon the Ethernet standard. Work began on Sercos III in 2003, with vendors releasing first products supporting it in 2005.
10 Gigabit Ethernet is a group of computer networking technologies for transmitting Ethernet frames at a rate of 10 gigabits per second. It was first defined by the IEEE 802.3ae-2002 standard. Unlike previous Ethernet standards, 10GbE defines only full-duplex point-to-point links which are generally connected by network switches; shared-medium CSMA/CD operation has not been carried over from the previous generations of Ethernet standards so half-duplex operation and repeater hubs do not exist in 10GbE. The first standard for faster 100 Gigabit Ethernet links was approved in 2010.
MOST is a high-speed multimedia network technology for the automotive industry. It can be used for applications inside or outside the car. The serial MOST bus uses a daisy-chain topology or ring topology and synchronous serial communication to transport audio, video, voice and data signals via plastic optical fiber (POF) or electrical conductor physical layers.
RAPIEnet was Korea's first Ethernet international standard for real-time data transmission. It is an Ethernet-based industrial networking protocol, developed in-house by LSIS offers real-time transmission and is registered as an international standard.