Names | High Throughput X-ray Spectroscopy Mission X-ray Multi-Mirror Mission | ||||||||
---|---|---|---|---|---|---|---|---|---|
Mission type | X-ray astronomy | ||||||||
Operator | European Space Agency | ||||||||
COSPAR ID | 1999-066A | ||||||||
SATCAT no. | 25989 | ||||||||
Website | http://sci.esa.int/xmm-newton/ http://xmm.esac.esa.int/ | ||||||||
Mission duration | Planned: 10 years [1] Elapsed: 24 years, 10 months, 4 days | ||||||||
Spacecraft properties | |||||||||
Manufacturer | Dornier Satellitensysteme, Carl Zeiss, Media Lario, Matra Marconi Space, BPD Difesa e Spazio, Fokker Space [2] | ||||||||
Launch mass | 3,764 kg (8,298 lb) [2] | ||||||||
Dry mass | 3,234 kg (7,130 lb) | ||||||||
Dimensions | Length: 10.8 m (35 ft) [2] Span: 16.16 m (53 ft) [2] | ||||||||
Power | 1,600 watts [2] | ||||||||
Start of mission | |||||||||
Launch date | 10 December 1999, 14:32 UTC [3] | ||||||||
Rocket | Ariane 5G No. 504 [4] | ||||||||
Launch site | Guiana Space Centre ELA-3 [2] [4] | ||||||||
Contractor | Arianespace | ||||||||
Entered service | 1 July 2000 [2] | ||||||||
End of mission | |||||||||
Deactivated | presumed end of 2026 or later [5] | ||||||||
Orbital parameters | |||||||||
Reference system | Geocentric | ||||||||
Semi-major axis | 65,648.3 km (40,792.0 mi) | ||||||||
Eccentricity | 0.816585 | ||||||||
Perigee altitude | 5,662.7 km (3,518.6 mi) | ||||||||
Apogee altitude | 112,877.6 km (70,138.9 mi) | ||||||||
Inclination | 67.1338 degrees | ||||||||
Period | 2789.9 minutes | ||||||||
Epoch | 4 February 2016, 01:06:30 UTC [6] | ||||||||
Main telescope | |||||||||
Type | 3 × Wolter type-1 [2] | ||||||||
Diameter | Outer mirror: 70 cm (28 in) [2] Inner mirror: 30.6 cm (12 in) [2] | ||||||||
Focal length | 7.5 m (25 ft) [2] | ||||||||
Collecting area | 0.4425 m2 (5 sq ft) at 1.5 keV [2] 0.1740 m2 (2 sq ft) at 8 keV [2] | ||||||||
Wavelengths | 0.1–12 keV (12–0.1 nm) [2] | ||||||||
Resolution | 5 to 14 arcseconds [2] | ||||||||
| |||||||||
ESA astrophysics insignia for XMM-Newton |
XMM-Newton, also known as the High Throughput X-ray Spectroscopy Mission and the X-ray Multi-Mirror Mission, is an X-ray space observatory launched by the European Space Agency in December 1999 on an Ariane 5 rocket. It is the second cornerstone mission of ESA's Horizon 2000 programme. Named after physicist and astronomer Sir Isaac Newton, the spacecraft is tasked with investigating interstellar X-ray sources, performing narrow- and broad-range spectroscopy, and performing the first simultaneous imaging of objects in both X-ray and optical (visible and ultraviolet) wavelengths. [7]
Initially funded for two years, with a ten-year design life, the spacecraft remains in good health and has received repeated mission extensions, most recently in March 2023 and is scheduled to operate until the end of 2026. [5] ESA plans to succeed XMM-Newton with the Advanced Telescope for High Energy Astrophysics (ATHENA), the second large mission in the Cosmic Vision 2015–2025 plan, to be launched in 2035. [8] XMM-Newton is similar to NASA's Chandra X-ray Observatory, also launched in 1999.
As of May 2018, close to 5,600 papers have been published about either XMM-Newton or the scientific results it has returned. [9]
The observational scope of XMM-Newton includes the detection of X-ray emissions from astronomical objects, detailed studies of star-forming regions, investigation of the formation and evolution of galaxy clusters, the environment of supermassive black holes and mapping of the mysterious dark matter. [10]
In 1982, even before the launch of XMM-Newton's predecessor EXOSAT in 1983, a proposal was generated for a "multi-mirror" X-ray telescope mission. [11] [12] The XMM mission was formally proposed to the ESA Science Programme Committee in 1984 and gained approval from the Agency's Council of Ministers in January 1985. [13] That same year, several working groups were established to determine the feasibility of such a mission, [11] and mission objectives were presented at a workshop in Denmark in June 1985. [12] [14] At this workshop, it was proposed that the spacecraft contain 12 low-energy and 7 high-energy X-ray telescopes. [14] [15] The spacecraft's overall configuration was developed by February 1987, and drew heavily from lessons learned during the EXOSAT mission; [11] the Telescope Working Group had reduced the number of X-ray telescopes to seven standardised units. [14] [15] In June 1988 the European Space Agency approved the mission and issued a call for investigation proposals (an "announcement of opportunity"). [11] [15] Improvements in technology further reduced the number of X-ray telescopes needed to just three. [15]
In June 1989, the mission's instruments had been selected and work began on spacecraft hardware. [11] [15] A project team was formed in January 1993 and based at the European Space Research and Technology Centre (ESTEC) in Noordwijk, Netherlands. [13] Prime contractor Dornier Satellitensysteme (a subsidiary of the former DaimlerChrysler Aerospace) was chosen in October 1994 after the mission was approved into the implementation phase, with development and construction beginning in March 1996 and March 1997, respectively. [13] [14] The XMM Survey Science Centre was established at the University of Leicester in 1995. [11] [16] The three flight mirror modules for the X-ray telescopes were delivered by Italian subcontractor Media Lario in December 1998, [14] and spacecraft integration and testing was completed in September 1999. [13]
XMM left the ESTEC integration facility on 9 September 1999, taken by road to Katwijk then by the barge Emeli to Rotterdam. On 12 September, the spacecraft left Rotterdam for French Guiana aboard Arianespace 's transport ship MN Toucan. [17] The Toucan docked at the French Guianese town of Kourou on 23 September, and was transported to Guiana Space Centre 's Ariane 5 Final Assembly Building for final launch preparation. [18]
Launch of XMM took place on 10 December 1999 at 14:32 UTC from the Guiana Space Centre. [19] XMM was lofted into space aboard an Ariane 5 rocket, and placed into a highly elliptical, 40-degree orbit that had a perigee of 838 km (521 mi) and an apogee of 112,473 km (69,887 mi). [2] Forty minutes after being released from the Ariane upper stage, telemetry confirmed to ground stations that the spacecraft's solar arrays had successfully deployed. Engineers waited an additional 22 hours before commanding the on-board propulsion systems to fire a total of five times, which, between 10 and 16 December, changed the orbit to 7,365 × 113,774 km (4,576 × 70,696 mi) with a 38.9-degree inclination. This resulted in the spacecraft making one complete revolution of the Earth approximately every 48 hours. [2] [20]
Immediately after launch, XMM began its Launch and Early Orbit phase of operations. [21] On 17 and 18 December 1999, the X-ray modules and Optical Monitor doors were opened, respectively. [22] Instrument activation started on 4 January 2000, [2] and the Instrument Commissioning phase began on 16 January. [23] The Optical Monitor (OM) attained first light on 5 January, the two European Photon Imaging Camera (EPIC) MOS-CCDs followed on 16 January and the EPIC pn-CCD on 22 January, and the Reflection Grating Spectrometers (RGS) saw first light on 2 February. [23] On 3 March, the Calibration and Performance Validation phase began, [2] and routine science operations began on 1 June. [23]
During a press conference on 9 February 2000, ESA presented the first images taken by XMM and announced that a new name had been chosen for the spacecraft. Whereas the program had formally been known as the High Throughput X-ray Spectroscopy Mission, the new name would reflect the nature of the program and the originator of the field of spectroscopy. Explaining the new name of XMM-Newton, Roger Bonnet, ESA's former Director of Science, said, "We have chosen this name because Sir Isaac Newton was the man who invented spectroscopy and XMM is a spectroscopy mission." He noted that because Newton is synonymous with gravity and one of the goals of the satellite was to locate large numbers of black hole candidates, "there was no better choice than XMM-Newton for the name of this mission." [24]
Including all construction, spacecraft launch, and two years of operation, the project was accomplished within a budget of €689 million (1999 conditions). [13] [14]
The spacecraft has the ability to lower the operating temperature of both the EPIC and RGS cameras, a function that was included to counteract the deleterious effects of ionising radiation on the camera pixels. In general, the instruments are cooled to reduce the amount of dark current within the devices. During the night of 3–4 November 2002, RGS-2 was cooled from its initial temperature of −80 °C (−112 °F) down to −113 °C (−171 °F), and a few hours later to −115 °C (−175 °F). After analysing the results, it was determined the optimal temperature for both RGS units would be −110 °C (−166 °F), and during 13–14 November, both RGS-1 and RGS-2 were set to this level. During 6–7 November, the EPIC MOS-CCD detectors were cooled from their initial operating temperature of −100 °C (−148 °F) to a new setting of −120 °C (−184 °F). After these adjustments, both the EPIC and RGS cameras showed dramatic improvements in quality. [25]
On 18 October 2008, XMM-Newton suffered an unexpected communications failure, during which time there was no contact with the spacecraft. While some concern was expressed that the vehicle may have suffered a catastrophic event, photographs taken by amateur astronomers at the Starkenburg Observatory in Germany and at other locations worldwide showed that the spacecraft was intact and appeared on course. A weak signal was finally detected using a 35-metre (115 ft) antenna in New Norcia, Western Australia, and communication with XMM-Newton suggested that the spacecraft's Radio Frequency switch had failed. After troubleshooting a solution, ground controllers used NASA's 34 m (112 ft) antenna at the Goldstone Deep Space Communications Complex to send a command that changed the switch to its last working position. ESA stated in a press release that on 22 October, a ground station at the European Space Astronomy Centre (ESAC) made contact with the satellite, confirming the process had worked and that the satellite was back under control. [26] [27] [28]
Because of the spacecraft's good health and the significant returns of data, XMM-Newton has received several mission extensions by ESA's Science Programme Committee. The first extension came during November 2003 and extended operations through March 2008. [29] The second extension was approved in December 2005, extending work through March 2010. [30] A third extension was passed in November 2007, which provided for operations through 2012. As part of the approval, it was noted that the satellite had enough on-board consumables (fuel, power and mechanical health) to theoretically continue operations past 2017. [31] The fourth extension in November 2010 approved operations through 2014. [32] A fifth extension was approved in November 2014 and affirmed in November 2016, continuing operations through 2018. [33] [34] A sixth extension was approved in December 2017, continuing operations through the end of 2020. [35] A seventh extension was approved in November 2018, continuing operations through the end of 2022. [36] An eighth extension was approved in March 2023, continuing operations through the end of 2026, with indicative extension up to 2029. [5]
XMM-Newton is a 10.8-metre (35 ft) long space telescope, and is 16.16 m (53 ft) wide with solar arrays deployed. At launch it weighed 3,764 kilograms (8,298 lb). [2] The spacecraft has three degrees of stabilisation, which allow it to aim at a target with an accuracy of 0.25 to 1 arcseconds. This stabilisation is achieved through the use of the spacecraft's Attitude & Orbit Control Subsystem. These systems also allow the spacecraft to point at different celestial targets, and can turn the craft at a maximum of 90 degrees per hour. [11] [24] The instruments on board XMM-Newton are three European Photon Imaging Cameras (EPIC), two Reflection Grating Spectrometers (RGS), and an Optical Monitor.
The spacecraft is roughly cylindrical in shape, and has four major components. At the fore of the spacecraft is the Mirror Support Platform, which supports the X-ray telescope assemblies and grating systems, the Optical Monitor, and two star trackers. Surrounding this component is the Service Module, which carries various spacecraft support systems: computer and electric busses, consumables (such as fuel and coolant), solar arrays, the Telescope Sun Shield, and two S-band antennas. Behind these units is the Telescope Tube, a 6.8-metre (22 ft) long, hollow carbon fibre structure which provides exact spacing between the mirrors and their detection equipment. This section also hosts outgassing equipment on its exterior, which helps remove any contaminants from the interior of the satellite. At the aft end of spacecraft is the Focal Plane Assembly, which supports the Focal Plane Platform (carrying the cameras and spectrometers) and the data-handling, power distribution, and radiator assemblies. [37]
The three European Photon Imaging Cameras (EPIC) are the primary instruments aboard XMM-Newton. The system is composed of two MOS–CCD cameras and a single pn-CCD camera, with a total field of view of 30 arcminutes and an energy sensitivity range between 0.15 and 15 keV (82.7 to 0.83 ångströms ). Each camera contains a six-position filter wheel, with three types of X-ray-transparent filters, a fully open and a fully closed position; each also contains a radioactive source used for internal calibration. The cameras can be independently operated in a variety of modes, depending on the image sensitivity and speed needed, as well as the intensity of the target. [38] [39] [40]
The two MOS-CCD cameras are used to detect low-energy X-rays. Each camera is composed of seven silicon chips (one in the centre and six circling it), with each chip containing a matrix of 600 × 600 pixels, giving the camera a total resolution of about 2.5 megapixels. As discussed above, each camera has a large adjacent radiator which cools the instrument to an operating temperature of −120 °C (−184 °F). They were developed and built by the University of Leicester Space Research Centre and EEV Ltd. [25] [38] [40]
The pn-CCD camera is used to detect high-energy X-rays, and is composed of a single silicon chip with twelve individual embedded CCDs. Each CCD is 64 × 189 pixels, for a total capacity of 145,000 pixels. At the time of its construction, the pn-CCD camera on XMM-Newton was the largest such device ever made, with a sensitive area of 36 cm2 (5.6 sq in). A radiator cools the camera to −90 °C (−130 °F). This system was made by the Astronomisches Institut Tübingen, the Max Planck Institute for Extraterrestrial Physics, and PNSensor, all of Germany. [38] [41] [42]
The EPIC system records three types of data about every X-ray that is detected by its CCD cameras. The time that the X-ray arrives allows scientists to develop light curves, which projects the number of X-rays that arrive over time and shows changes in the brightness of the target. Where the X-ray hits the camera allows for a visible image to be developed of the target. The amount of energy carried by the X-ray can also be detected and helps scientists to determine the physical processes occurring at the target, such as its temperature, its chemical make-up, and what the environment is like between the target and the telescope. [43]
The Reflection Grating Spectrometers (RGS) are composed of two Focal Plane Cameras and their associated Reflection Grating Arrays. This system is used to build X-ray spectral data and can determine the elements present in the target, as well as the temperature, quantity and other characteristics of those elements. The RGS system operates in the 2.5 to 0.35 keV (5 to 35 ångström) range, which allows detection of carbon, nitrogen, oxygen, neon, magnesium, silicon and iron. [44] [45]
The Focal Plane Cameras each consist of nine MOS-CCD devices mounted in a row and following a curve called a Rowland circle. Each CCD contains 384 × 1024 pixels, for a total resolution of more than 3.5 megapixels. The total width and length of the CCD array was dictated by the size of the RGS spectrum and the wavelength range, respectively. Each CCD array is surrounded by a relatively massive wall, providing heat conduction and radiation shielding. Two-stage radiators cool the cameras to an operating temperature of −110 °C (−166 °F). The camera systems were a joint effort between SRON, the Paul Scherrer Institute, and MSSL, with EEV Ltd and Contraves Space providing hardware. [25] [44] [45] [46] [47]
The Reflection Grating Arrays are attached to two of the primary telescopes. They allow approximately 50% of the incoming X-rays to pass unperturbed to the EPIC system, while redirecting the other 50% onto the Focal Plane Cameras. Each RGA was designed to contain 182 identical gratings, though a fabrication error left one with only 181. Because the telescope mirrors have already focused the X-rays to converge at the focal point, each grating has the same angle of incidence, and as with the Focal Plane Cameras, each grating array conforms to a Rowland circle. This configuration minimises focal aberrations. Each 10 × 20 cm (4 × 8 in) grating is composed of 1 mm (0.039 in) thick silicon carbide substrate covered with a 2,000- ångström (7.9×10−6 in) gold film, and is supported by five beryllium stiffeners. The gratings contain a large number of grooves, which actually perform the X-ray deflection; each grating contains an average of 646 grooves per millimetre. The RGAs were built by Columbia University. [44] [45]
The Optical Monitor (OM) is a 30 cm (12 in) Ritchey–Chrétien optical/ultraviolet telescope designed to provide simultaneous observations alongside the spacecraft's X-ray instruments. The OM is sensitive between 170 and 650 nanometres in a 17 × 17 arcminute square field of view co-aligned with the centre of the X-ray telescope's field of view. It has a focal length of 3.8 m (12 ft) and a focal ratio of ƒ/12.7. [48] [49]
The instrument is composed of the Telescope Module, containing the optics, detectors, processing equipment, and power supply; and the Digital Electronics Module, containing the instrument control unit and data processing units. Incoming light is directed into one of two fully redundant detector systems. The light passes through an 11-position filter wheel (one opaque to block light, six broad band filters, one white light filter, one magnifier, and two grisms), then through an intensifier which amplifies the light by one million times, then onto the CCD sensor. The CCD is 384 × 288 pixels in size, of which 256 × 256 pixels are used for observations; each pixel is further subsampled into 8 × 8 pixels, resulting in a final product that is 2048 × 2048 in size. The Optical Monitor was built by the Mullard Space Science Laboratory with contributions from organisations in the United States and Belgium. [48] [49]
Feeding the EPIC and RGS systems are three telescopes designed specifically to direct X-rays into the spacecraft's primary instruments. The telescope assemblies each have a diameter of 90 cm (35 in), are 250 cm (98 in) in length, and have a base weight of 425 kg (937 lb). The two telescopes with Reflection Grating Arrays weigh an additional 20 kg (44 lb). Components of the telescopes include (from front to rear) the mirror assembly door, entrance and X-ray baffles, mirror module, electron deflector, a Reflection Grating Array in two of the assemblies, and exit baffle. [13] [50] [51] [52]
Each telescope consists of 58 cylindrical, nested Wolter Type-1 mirrors developed by Media Lario of Italy, each 600 mm (24 in) long and ranging in diameter from 306 to 700 mm (12.0 to 27.6 in), producing a total collecting area of 4,425 cm2 (686 sq in) at 1.5 keV and 1,740 cm2 (270 sq in) at 8 keV. [2] The mirrors range from 0.47 mm (0.02 in) thick for the innermost mirror to 1.07 mm (0.04 in) thick for the outermost mirror, and the separation between each mirror ranges from 1.5 to 4 mm (0.06 to 0.16 in) from innermost to outermost. [2] Each mirror was built by vapour-depositing a 250 nm layer of gold reflecting surface onto a highly polished aluminium mandrel, followed by electroforming a monolithic nickel support layer onto the gold. The finished mirrors were glued into the grooves of an Inconel spider, which keeps them aligned to within the five-micron tolerance required to achieve adequate X-ray resolution. The mandrels were manufactured by Carl Zeiss AG, and the electroforming and final assembly were performed by Media Lario with contributions from Kayser-Threde. [53]
Spacecraft three-axis attitude control is handled by the Attitude & Orbit Control System (AOCS), composed of four reaction wheels, four inertial measurement units, two star trackers, three fine Sun sensors, and three Sun acquisition sensors. The AOCS was provided by Matra Marconi Space of the United Kingdom. [2] [54] [55]
Coarse spacecraft orientation and orbit maintenance is provided by two sets of four 20- newton (4.5 lbf ) hydrazine thrusters (primary and backup). [2] The hydrazine thrusters were built by DASA-RI of Germany. [56]
The AOCS was upgraded in 2013 with a software patch ('4WD'), to control attitude using the 3 prime reaction wheels plus the 4th, spare wheel, unused since launch, with the aim of saving propellant to extend the spacecraft lifetime. [57] [58] In 2019 the fuel was predicted to last until 2030. [59]
Primary power for XMM-Newton is provided by two fixed solar arrays. The arrays are composed of six panels measuring 1.81 × 1.94 m (5.9 × 6.4 ft) for a total of 21 m2 (230 sq ft) and a mass of 80 kg (180 lb). At launch, the arrays provided 2,200 W of power, and were expected to provide 1,600 W after ten years of operation. Deployment of each array took four minutes. The arrays were provided by Fokker Space of the Netherlands. [2] [60]
When direct sunlight is unavailable, power is provided by two nickel–cadmium batteries providing 24 A·h and weighing 41 kg (90 lb) each. The batteries were provided by SAFT of France. [2] [60]
The cameras are accompanied by the EPIC Radiation Monitor System (ERMS), which measures the radiation environment surrounding the spacecraft; specifically, the ambient proton and electron flux. This provides warning of damaging radiation events to allow for automatic shut-down of the sensitive camera CCDs and associated electronics. The ERMS was built by the Centre d'Etude Spatiale des Rayonnements of France. [13] [38] [40]
The Visual Monitoring Cameras (VMC) on the spacecraft were added to monitor the deployment of solar arrays and the sun shield, and have additionally provided images of the thrusters firing and outgassing of the Telescope Tube during early operations. Two VMCs were installed on the Focal Plane Assembly looking forward. The first is FUGA-15, a black and white camera with high dynamic range and 290 × 290 pixel resolution. The second is IRIS-1, a colour camera with a variable exposure time and 400 × 310 pixel resolution. Both cameras measure 6 × 6 × 10 cm (2.4 × 2.4 × 3.9 in) and weight 430 g (15 oz). They use active pixel sensors, a technology that was new at the time of XMM-Newton's development. The cameras were developed by OIC–Delft and IMEC, both of Belgium. [56] [61]
XMM-Newton mission control is located at the European Space Operations Centre (ESOC) in Darmstadt, Germany. Two ground stations, located in Perth and Kourou, are used to maintain continuous contact with the spacecraft through most of its orbit. Back-up ground stations are located in Villafranca del Castillo, Santiago, and Dongara. Because XMM-Newton contains no on-board data storage, science data is transmitted to these ground stations in real time. [20]
Data is then forwarded to the European Space Astronomy Centre 's Science Operations Centre in Villafranca del Castillo, Spain, where pipeline processing has been performed since March 2012. Data is archived at the ESAC Science Data Centre, [62] and distributed to mirror archives at the Goddard Space Flight Center and the XMM-Newton Survey Science Centre (SSC) at the Institut de Recherche en Astrophysique et Planétologie. Prior to June 2013, the SSC was operated by the University of Leicester, but operations were transferred due to a withdrawal of funding by the United Kingdom. [16] [63]
The space observatory was used to discover the galaxy cluster XMMXCS 2215-1738, 10 billion light years away from Earth. [64]
The object SCP 06F6, discovered by the Hubble Space Telescope (HST) in February 2006, was observed by XMM-Newton in early August 2006 and appeared to show an X-ray glow around it [65] two orders of magnitude more luminous than that of supernovae. [66]
In June 2011, a team from the University of Geneva, Switzerland, reported XMM-Newton seeing a flare that lasted four hours at a peak intensity of 10,000 times the normal rate, from an observation of Supergiant Fast X-ray Transient IGR J18410-0535, where a blue supergiant star shed a plume of matter that was partly ingested by a smaller companion neutron star with accompanying X-ray emissions. [67] [68]
In February 2013 it was announced that XMM-Newton along with NuSTAR have for the first time measured the spin rate of a supermassive black hole, by observing the black hole at the core of galaxy NGC 1365. At the same time, it verified the model that explains the distortion of X-rays emitted from a black hole. [69] [70]
In February 2014, separate analyses extracted from the spectrum of X-ray emissions observed by XMM-Newton a monochromatic signal around 3.5 keV. [71] [72] This signal is coming from different galaxy clusters, and several scenarios of dark matter can justify such a line. For example, a 3.5 keV candidate annihilating into 2 photons, [73] or a 7 keV dark matter particle decaying into photon and neutrino. [74]
In June 2021, one of the largest X-ray surveys using the European Space Agency's XMM-Newton space observatory published initial findings, mapping the growth of 12,000 supermassive black holes at the cores of galaxies and galaxy clusters. [75]
SMART-1 was a Swedish-designed European Space Agency satellite that orbited the Moon. It was launched on 27 September 2003 at 23:14 UTC from the Guiana Space Centre in Kourou, French Guiana. "SMART-1" stands for Small Missions for Advanced Research in Technology-1. On 3 September 2006, SMART-1 was deliberately crashed into the Moon's surface, ending its mission.
The Chandra X-ray Observatory (CXO), previously known as the Advanced X-ray Astrophysics Facility (AXAF), is a Flagship-class space telescope launched aboard the Space ShuttleColumbia during STS-93 by NASA on July 23, 1999. Chandra was sensitive to X-ray sources 100 times fainter than any previous X-ray telescope, enabled by the high angular resolution of its mirrors. Since the Earth's atmosphere absorbs the vast majority of X-rays, they are not detectable from Earth-based telescopes; therefore space-based telescopes are required to make these observations. Chandra is an Earth satellite in a 64-hour orbit, and its mission is ongoing as of 2024.
The Wide Field and Planetary Camera 2 (WFPC2) is a camera formerly installed on the Hubble Space Telescope. The camera was built by the Jet Propulsion Laboratory and is roughly the size of a baby grand piano. It was installed by servicing mission 1 (STS-61) in 1993, replacing the telescope's original Wide Field and Planetary Camera (WF/PC). WFPC2 was used to image the Hubble Deep Field in 1995, the Engraved Hourglass Nebula and Egg Nebula in 1996, and the Hubble Deep Field South in 1998. During STS-125, WFPC2 was removed and replaced with the Wide Field Camera 3 as part of the mission's first spacewalk on May 14, 2009. After returning to Earth, the camera was displayed briefly at the National Air and Space Museum and the Jet Propulsion Laboratory before returning to its final home at the Smithsonian's National Air and Space Museum.
The Herschel Space Observatory was a space observatory built and operated by the European Space Agency (ESA). It was active from 2009 to 2013, and was the largest infrared telescope ever launched until the launch of the James Webb Space Telescope in 2021. Herschel carries a 3.5-metre (11.5 ft) mirror and instruments sensitive to the far infrared and submillimetre wavebands (55–672 μm). Herschel was the fourth and final cornerstone mission in the Horizon 2000 programme, following SOHO/Cluster II, XMM-Newton and Rosetta.
The Constellation-X Observatory was a mission concept for an X-ray space observatory to be operated by NASA; in 2008 it was merged with ESA and JAXA efforts in the same direction to produce the International X-ray Observatory project, announced on 24 July 2008.
The INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL) is a space telescope for observing gamma rays of energies up to 8 MeV. It was launched by the European Space Agency (ESA) into Earth orbit in 2002, and is designed to provide imaging and spectroscopy of cosmic sources. In the MeV energy range, it is the most sensitive gamma ray observatory in space. It is sensitive to higher energy photons than X-ray instruments such as NuSTAR, the Neil Gehrels Swift Observatory, XMM-Newton, and lower than other gamma-ray instruments such Fermi and HESS.
The NASA Infrared Telescope Facility is a 3-meter (9.8 ft) telescope optimized for use in infrared astronomy and located at the Mauna Kea Observatory in Hawaii. It was first built to support the Voyager missions and is now the US national facility for infrared astronomy, providing continued support to planetary, solar neighborhood, and deep space applications. The IRTF is operated by the University of Hawaii under a cooperative agreement with NASA. According to the IRTF's time allocation rules, at least 50% of the observing time is devoted to planetary science.
NuSTAR is a NASA space-based X-ray telescope that uses a conical approximation to a Wolter telescope to focus high energy X-rays from astrophysical sources, especially for nuclear spectroscopy, and operates in the range of 3 to 79 keV.
An X-ray telescope (XRT) is a telescope that is designed to observe remote objects in the X-ray spectrum. X-rays are absorbed by the Earth's atmosphere, so instruments to detect X-rays must be taken to high altitude by balloons, sounding rockets, and satellites.
XEUS was a space observatory plan developed by the European Space Agency (ESA) as a successor to the successful XMM-Newton X-ray satellite telescope. It was merged to the International X-ray Observatory (IXO) around 2008, but as that project ran into issues in 2011, the ESA component was forked off into Advanced Telescope for High Energy Astrophysics (Athena).
SRON Netherlands Institute for Space Research (SRON) is the Dutch national institute for space research. It focuses on astrophysics, Earth observation, and exoplanetary research. SRON also develops new detection techniques for X-rays, infrared radiation, and visible light. As national expertise institute, SRON gives council to the Dutch government and coordinates national contributions to international space missions.
Advanced Telescope for High-ENergy Astrophysics (Athena) is an X-ray observatory mission selected by European Space Agency (ESA) within its Cosmic Vision program to address the Hot and Energetic Universe scientific theme. Athena will operate in the energy range of 0.2–12 keV and will offer spectroscopic and imaging capabilities exceeding those of currently operating X-ray astronomy satellites – e.g. the Chandra X-ray Observatory and XMM-Newton – by at least one order of magnitude on several parameter spaces simultaneously.
PLAnetary Transits and Oscillations of stars (PLATO) is a space telescope under development by the European Space Agency for launch in 2026. The mission goals are to search for planetary transits across up to one million stars, and to discover and characterize rocky extrasolar planets around yellow dwarf stars, subgiant stars, and red dwarf stars. The emphasis of the mission is on Earth-like planets in the habitable zone around Sun-like stars where water can exist in a liquid state. It is the third medium-class mission in ESA's Cosmic Vision programme and is named after the influential Greek philosopher Plato. A secondary objective of the mission is to study stellar oscillations or seismic activity in stars to measure stellar masses and evolution and enable the precise characterization of the planet host star, including its age.
Euclid is a wide-angle space telescope with a 600-megapixel camera to record visible light, a near-infrared spectrometer, and photometer, to determine the redshift of detected galaxies. It was developed by the European Space Agency (ESA) and the Euclid Consortium and was launched on 1 July 2023 from Cape Canaveral in Florida.
The International X-ray Observatory (IXO) is a cancelled X-ray telescope that was to be launched in 2021 as a joint effort by NASA, the European Space Agency (ESA), and the Japan Aerospace Exploration Agency (JAXA). In May 2008, ESA and NASA established a coordination group involving all three agencies, with the intent of exploring a joint mission merging the ongoing XEUS and Constellation-X Observatory (Con-X) projects. This proposed the start of a joint study for IXO. NASA was forced to cancel the observatory due to budget constraints in fiscal year 2012. ESA however decided to reboot the mission on its own developing Advanced Telescope for High Energy Astrophysics as a part of Cosmic Vision program.
Solar wind Magnetosphere Ionosphere Link Explorer (SMILE) is a planned joint venture mission between the European Space Agency and the Chinese Academy of Sciences. SMILE will image for the first time the magnetosphere of the Sun in soft X-rays and UV during up to 40 hours per orbit, improving our understanding of the dynamic interaction between the solar wind and Earth's magnetosphere. The prime science questions of the SMILE mission are
The X-Ray Imaging and Spectroscopy Mission, formerly the X-ray Astronomy Recovery Mission (XARM), is an X-ray space telescope mission of the Japan Aerospace Exploration Agency (JAXA) in partnership with NASA to provide breakthroughs in the study of structure formation of the universe, outflows from galaxy nuclei, and dark matter. As the only international X-ray observatory project of its period, XRISM will function as a next generation space telescope in the X-ray astronomy field, similar to how the James Webb Space Telescope, Fermi Space Telescope, and the Atacama Large Millimeter Array (ALMA) Observatory are placed in their respective fields.
The Lynx X-ray Observatory (Lynx) is a NASA-funded Large Mission Concept Study commissioned as part of the National Academy of Sciences 2020 Astronomy and Astrophysics Decadal Survey. The concept study phase is complete as of August 2019, and the Lynx final report has been submitted to the Decadal Survey for prioritization. If launched, Lynx would be the most powerful X-ray astronomy observatory constructed to date, enabling order-of-magnitude advances in capability over the current Chandra X-ray Observatory and XMM-Newton space telescopes.
The Science Programme of the European Space Agency is a long-term programme of space science and space exploration missions. Managed by the agency's Directorate of Science, The programme funds the development, launch, and operation of missions led by European space agencies and institutions through generational campaigns. Horizon 2000, the programme's first campaign, facilitated the development of eight missions between 1985 and 1995 including four "cornerstone missions" – SOHO and Cluster II, XMM-Newton, Rosetta, and Herschel. Horizon 2000 Plus, the programme's second campaign, facilitated the development of Gaia, LISA Pathfinder, and BepiColombo between 1995 and 2005. The programme's current campaign since 2005, Cosmic Vision, has so far funded the development of ten missions including three flagship missions, JUICE, Athena, and LISA. The programme's upcoming fourth campaign, Voyage 2050, is currently being drafted. Collaboration with agencies and institutions outside of Europe occasionally occur in the Science Programme, including a collaboration with NASA on Cassini–Huygens and the CNSA on SMILE.