Thalmann algorithm

Last updated

The Thalmann Algorithm (VVAL 18) is a deterministic decompression model originally designed in 1980 to produce a decompression schedule for divers using the US Navy Mk15 rebreather. [1] It was developed by Capt. Edward D. Thalmann, MD, USN, who did research into decompression theory at the Naval Medical Research Institute, Navy Experimental Diving Unit, State University of New York at Buffalo, and Duke University. The algorithm forms the basis for the current US Navy mixed gas and standard air dive tables (from US Navy Diving Manual Revision 6). [2] The decompression model is also referred to as the Linear–Exponential model or the Exponential–Linear model. [3]

Contents

History

The Mk15 rebreather supplies a constant partial pressure of oxygen of 0.7 bar (70 kPa) with nitrogen as the inert gas. Prior to 1980 it was operated using schedules from printed tables. It was determined that an algorithm suitable for programming into an underwater decompression monitor (an early dive computer) would offer advantages. This algorithm was initially designated "MK15 (VVAL 18) RTA", a real-time algorithm for use with the Mk15 rebreather. [4]

Description

VVAL 18 is a deterministic model that utilizes the Naval Medical Research Institute Linear Exponential (NMRI LE1 PDA) data set for calculation of decompression schedules. Phase two testing of the US Navy Diving Computer produced an acceptable algorithm with an expected maximum incidence of decompression sickness (DCS) less than 3.5% assuming that occurrence followed the binomial distribution at the 95% confidence level.

Response of a tissue compartment to a step increase and decrease in pressure showing Exponential-Exponential and two possibilities for Linear-Exponential uptake and washout Linear-Exponential tussue tensions.png
Response of a tissue compartment to a step increase and decrease in pressure showing Exponential-Exponential and two possibilities for Linear-Exponential uptake and washout

The use of simple symmetrical exponential gas kinetics models has shown up the need for a model that would give slower tissue washout. In the early 1980s the US Navy Experimental Diving Unit developed an algorithm using a decompression model with exponential gas absorption as in the usual Haldanian model, but a slower linear release during ascent. The effect of adding linear kinetics to the exponential model is to lengthen the duration of risk accumulation for a given compartment time constant. [5]

The model was originally developed for programming decompression computers for constant oxygen partial pressure closed circuit rebreathers. [6] [7] Initial experimental diving using an exponential-exponential algorithm resulted in an unacceptable incidence of DCS, so a change was made to a model using the linear release model, with a reduction in DCS incidence. The same principles were applied to developing an algorithm and tables for a constant oxygen partial pressure model for Heliox diving [3]

The linear component is active when the tissue pressure exceeds ambient pressure by a given amount specific to the tissue compartment. When the tissue pressure drops below this cross-over criterion the tissue is modelled by exponential kinetics. During gas uptake tissue pressure never exceeds ambient, so it is always modelled by exponential kinetics. This results in a model with the desired asymmetrical characteristics of slower washout than uptake. [8] The linear/exponential transition is smooth. Choice of cross-over pressure determines the slope of the linear region as equal to the slope of the exponential region at the cross-over point.

During the development of these algorithms and tables, it was recognized that a successful algorithm could be used to replace the existing collection of incompatible tables for various air and Nitrox diving modes currently in the US Navy Diving Manual with a set of mutually compatible decompression tables based on a single model, which was proposed by Gerth and Doolette in 2007. [9] This has been done in Revision 6 of the US Navy Diving Manual published in 2008, though some changes were made.

An independent implementation of the EL-Real Time Algorithm was developed by Cochran Consulting, Inc. for the diver-carried Navy Dive Computer under the guidance of E. D. Thalmann. [10]

Physiological interpretation

Computer testing of a theoretical bubble growth model reported by Ball, Himm, Homer and Thalmann produced results which led to the interpretation of the three compartments used in the probabilistic LE model, with fast (1.5min), intermediate (51 min) and slow (488min) time constants, of which only the intermediate compartment uses the linear kinetics modification during decompression, as possibly not representing distinct anatomically identifiable tissues, but three different kinetic processes which relate to different elements of DCS risk. [11]

They conclude that bubble evolution may not be sufficient to explain all aspects of DCS risk, and the relationship between gas phase dynamics and tissue injury requires further investigation. [12]

Related Research Articles

<span class="mw-page-title-main">Decompression sickness</span> Disorder caused by dissolved gases emerging from solution

Decompression sickness is a medical condition caused by dissolved gases emerging from solution as bubbles inside the body tissues during decompression. DCS most commonly occurs during or soon after a decompression ascent from underwater diving, but can also result from other causes of depressurisation, such as emerging from a caisson, decompression from saturation, flying in an unpressurised aircraft at high altitude, and extravehicular activity from spacecraft. DCS and arterial gas embolism are collectively referred to as decompression illness.

<span class="mw-page-title-main">Dive computer</span> Instrument to calculate decompression status in real time

A dive computer, personal decompression computer or decompression meter is a device used by an underwater diver to measure the elapsed time and depth during a dive and use this data to calculate and display an ascent profile which, according to the programmed decompression algorithm, will give a low risk of decompression sickness.

The Bühlmann decompression algorithm is a mathematical model (algorithm) of the way in which inert gases enter and leave the human body as the ambient pressure changes. Versions are used to create Bühlmann decompression tables and in personal dive computers to compute no-decompression limits and decompression schedules for dives in real-time. These decompression tables allow divers to plan the depth and duration for dives and the required decompression stops.

<span class="mw-page-title-main">Submarine Escape Immersion Equipment</span> Whole-body exposure suit that allows submariners to escape from a sunken submarine

Submarine Escape Immersion Equipment (SEIE), also known as Submarine Escape and Immersion Equipment, is a whole-body suit and one-man life raft that was first produced in 1952. It was designed by British company RFD Beaufort Limited and allows submariners to escape from a sunken submarine. The suit also provides protection against hypothermia and has replaced the Steinke hood rescue device. The suit allows survivors to escape a disabled submarine at depths down to 600 feet (183 m), with an ascent speed of 2–3 meters/second, at a rate of eight or more sailors per hour.

<span class="mw-page-title-main">Edward D. Thalmann</span> American hyperbaric medicine specialist and decompression researcher

Capt. Edward Deforest Thalmann, USN (ret.) was an American hyperbaric medicine specialist who was principally responsible for developing the current United States Navy dive tables for mixed-gas diving, which are based on his eponymous Thalmann Algorithm (VVAL18). At the time of his death, Thalmann was serving as assistant medical director of the Divers Alert Network (DAN) and an assistant clinical professor in anesthesiology at Duke University's Center for Hyperbaric Medicine and Environmental Physiology.

In physiology, isobaric counterdiffusion (ICD) is the diffusion of different gases into and out of tissues while under a constant ambient pressure, after a change of gas composition, and the physiological effects of this phenomenon. The term inert gas counterdiffusion is sometimes used as a synonym, but can also be applied to situations where the ambient pressure changes. It has relevance in mixed gas diving and anesthesiology.

<span class="mw-page-title-main">United States Navy Experimental Diving Unit</span> The primary source of diving and hyperbaric operational guidance for the US Navy

The United States Navy Experimental Diving Unit is the primary source of diving and hyperbaric operational guidance for the US Navy. It is located within the Naval Support Activity Panama City in Panama City Beach, Bay County, Florida.

Professor Albert Alois Bühlmann was a Swiss physician who was principally responsible for a number of important contributions to decompression science at the Laboratory of Hyperbaric Physiology at the University Hospital in Zürich, Switzerland. His impact on diving ranged from complex commercial and military diving to the occasional recreational diver. He is held in high regard for his professional ethics and attention to his research subjects.

<span class="mw-page-title-main">Decompression (diving)</span> Pressure reduction and its effects during ascent from depth

The decompression of a diver is the reduction in ambient pressure experienced during ascent from depth. It is also the process of elimination of dissolved inert gases from the diver's body which accumulate during ascent, largely during pauses in the ascent known as decompression stops, and after surfacing, until the gas concentrations reach equilibrium. Divers breathing gas at ambient pressure need to ascend at a rate determined by their exposure to pressure and the breathing gas in use. A diver who only breathes gas at atmospheric pressure when free-diving or snorkelling will not usually need to decompress, Divers using an atmospheric diving suit do not need to decompress as they are never exposed to high ambient pressure.

<span class="mw-page-title-main">Decompression practice</span> Techniques and procedures for safe decompression of divers

The practice of decompression by divers comprises the planning and monitoring of the profile indicated by the algorithms or tables of the chosen decompression model, to allow asymptomatic and harmless release of excess inert gases dissolved in the tissues as a result of breathing at ambient pressures greater than surface atmospheric pressure, the equipment available and appropriate to the circumstances of the dive, and the procedures authorized for the equipment and profile to be used. There is a large range of options in all of these aspects.

<span class="mw-page-title-main">History of decompression research and development</span> Chronological list of notable events in the history of diving decompression.

Decompression in the context of diving derives from the reduction in ambient pressure experienced by the diver during the ascent at the end of a dive or hyperbaric exposure and refers to both the reduction in pressure and the process of allowing dissolved inert gases to be eliminated from the tissues during this reduction in pressure.

<span class="mw-page-title-main">Decompression theory</span> Theoretical modelling of decompression physiology

Decompression theory is the study and modelling of the transfer of the inert gas component of breathing gases from the gas in the lungs to the tissues and back during exposure to variations in ambient pressure. In the case of underwater diving and compressed air work, this mostly involves ambient pressures greater than the local surface pressure, but astronauts, high altitude mountaineers, and travellers in aircraft which are not pressurised to sea level pressure, are generally exposed to ambient pressures less than standard sea level atmospheric pressure. In all cases, the symptoms caused by decompression occur during or within a relatively short period of hours, or occasionally days, after a significant pressure reduction.

<span class="mw-page-title-main">Decompression equipment</span> Equipment used by divers to facilitate decompression

There are several categories of decompression equipment used to help divers decompress, which is the process required to allow divers to return to the surface safely after spending time underwater at higher ambient pressures.

Brian Andrew Hills, born 19 March 1934 in Cardiff, Wales, died 13 January 2006 in Brisbane, Queensland, was a physiologist who worked on decompression theory.

<span class="mw-page-title-main">Thermodynamic model of decompression</span> Early model in which decompression is controlled by the volume of gas bubbles coming out of solution

The thermodynamic model was one of the first decompression models in which decompression is controlled by the volume of gas bubbles coming out of solution. In this model, pain only DCS is modelled by a single tissue which is diffusion-limited for gas uptake and bubble-formation during decompression causes "phase equilibration" of partial pressures between dissolved and free gases. The driving mechanism for gas elimination in this tissue is inherent unsaturation, also called partial pressure vacancy or the oxygen window, where oxygen metabolised is replaced by more soluble carbon dioxide. This model was used to explain the effectiveness of the Torres Straits Island pearl divers empirically developed decompression schedules, which used deeper decompression stops and less overall decompression time than the current naval decompression schedules. This trend to deeper decompression stops has become a feature of more recent decompression models.

<span class="mw-page-title-main">Physiology of decompression</span> The physiological basis for decompression theory and practice

The physiology of decompression is the aspect of physiology which is affected by exposure to large changes in ambient pressure, and involves a complex interaction of gas solubility, partial pressures and concentration gradients, diffusion, bulk transport and bubble mechanics in living tissues. Gas is breathed at ambient pressure, and some of this gas dissolves into the blood and other fluids. Inert gas continues to be taken up until the gas dissolved in the tissues is in a state of equilibrium with the gas in the lungs,, or the ambient pressure is reduced until the inert gases dissolved in the tissues are at a higher concentration than the equilibrium state, and start diffusing out again.

Henry Valence "Val" Hempleman was a researcher in the field of diving decompression.

The US Navy has used several decompression models from which their published decompression tables and authorized diving computer algorithms have been derived. The original C&R tables used a classic multiple independent parallel compartment model based on the work of J.S.Haldane in England in the early 20th century, using a critical ratio exponential ingassing and outgassing model. Later they were modified by O.D. Yarborough and published in 1937. A version developed by Des Granges was published in 1956. Further developments by M.W. Goodman and Robert D. Workman using a critical supersaturation approach to incorporate M-values, and expressed as an algorithm suitable for programming were published in 1965, and later again a significantly different model, the VVAL 18 exponential/linear model was developed by Edward D. Thalmann, using an exponential ingassing model and a combined exponential and linear outgassing model, which was further developed by Gerth and Doolette and published in Revision 6 of the US Navy Diving Manual as the 2008 tables.

References

  1. Thalmann, Edward D; Buckingham, IPB; Spaur, WH (1980). "Testing of decompression algorithms for use in the U.S. Navy underwater decompression computer (Phase I)". Navy Experimental Diving Unit Research Report. 11–80. Archived from the original on April 15, 2013. Retrieved 2008-03-16.{{cite journal}}: CS1 maint: unfit URL (link)
  2. Staff (September 2008). "VVAL-18M: New algorithm on deck for Navy divers". Diver Magazine. 33 (7). Archived from the original on July 10, 2011.{{cite journal}}: CS1 maint: unfit URL (link)
  3. 1 2 Thalmann 1985a , p. 6
  4. Thalmann, Edward D (2003). "Suitability of the USN MK15(VVAL18) Decompression Algorithm for Air Diving". Navy Experimental Diving Unit Research Report. 03–12. Archived from the original on April 15, 2013. Retrieved 2008-03-16.{{cite journal}}: CS1 maint: unfit URL (link)
  5. Parker et al. 1992 , p. 1
  6. Thalmann 1984 , abstract
  7. Huggins 1992 , chpt. 4 page 13
  8. Parker et al. 1992 , p. 3
  9. Gerth & Doolette 2007 , p. 1
  10. Gerth & Doolette 2007 , p. 2
  11. Ball 1995 , p. 272
  12. Ball 1995 , p. 273

Sources